China Case Study on ECS-7000MT Cooling Tower Energy-Saving Controller and Central Air Conditioning Energy Management System - China Supplier China Case Study on ECS-7000MT Cooling Tower Energy-Saving Controller and Central Air Conditioning Energy Management System - China Supplier China Case Study on ECS-7000MT Cooling Tower Energy-Saving Controller and Central Air Conditioning Energy Management System - China Supplier

Case Study on ECS-7000MT Cooling Tower Energy-Saving Controller and Central Air Conditioning Energy Management System

Price:Negotiable
Industry Category: Measurement-Analysis-Instruments
Product Category:
Brand: 西安
Spec:


Contact Info
  • Add:陕西省西安市翠华路60号, Zip:
  • Contact: 刘品宜
  • Tel:13572979371
  • Email:243616989@qq.com

Other Products

Description
Additional Information

ECS-7000 Overview of Integrated Building Equipment Monitoring System:

The integrated building equipment monitoring system utilizes intelligent devices that integrate power distribution, control, energy efficiency, energy consumption measurement and analysis, safety alarms, and fieldbus communication to efficiently monitor and manage the building's HVAC/fresh air systems, ventilation, pumps, elevators, lighting, and other electromechanical equipment. The building equipment energy-saving controller should be installed within the power distribution cabinet of the controlled equipment. The controller should integrate relevant secondary circuit systems such as relays within the power distribution cabinet, employing sub-item energy consumption measurement, analysis, energy-saving control strategies, and fieldbus technology to reduce the operational energy consumption of building electromechanical equipment. 3. HVAC/Fresh Air Unit System

Monitor the actual electrical power, supply/return air temperature, CO2 concentration, etc., of the unit.

Automatically adjust the opening of cold/hot water valves and fresh/return air dampers to effectively control the system's fresh/return air ratio, total fresh/return air volume, cold/hot water flow, and fan efficiency under different seasons and operating conditions.

Design Basis for Integrated Building Equipment Monitoring System

GB 50189-2015 "Design Code for Heating, Ventilation and Air Conditioning of Civil Buildings"

JGJ/T229-2010 "Green Design Standard for Civil Buildings"

GB 50736-2012 "Energy Efficiency Design Standard for Public Buildings"

GB 51348-2019 "Standard for Electrical Design of Civil Buildings"

50034-2013 "Standard for Lighting Design of Buildings"

GBT50378-2014 "Assessment Standard for Green Building"

GB/T26759-2011 "Technical Specification for Energy-Saving Control Devices of Central Air Conditioning Water Systems"

ECS7000S Green Building Equipment and Energy Management System Selection:

ECS-7000S Building Equipment Energy Efficiency Monitoring and Energy Consumption Statistical Analysis Software

ECS-7000MG Network Controller

ECS-7000MB/Sewage Pump Energy Efficiency Controller

ECS-7000MF/Ventilation Fan Energy Efficiency Controller

ECS7000MKT/Air Conditioning/Fresh Air Unit Energy-Saving Controller

ECS-7000MDF Chilled Water Energy-Saving Controller

ECS-7000MZK Pipe Network Energy-Saving Controller

ECS-7000MT Cooling Tower Energy-Saving Controller

ECS-7000MLS Unit Energy-Saving Controller

ECS7000MKT/Air Conditioning/Fresh Air Unit Energy-Saving Controller

Product Features

● Integrates secondary circuits of air conditioning/fresh air unit electrical control boxes.

● Manual remote-automatic control, interlock control, fan status display, duct temperature and humidity measurement, water valve adjustment, damper control, filter status display, CO2 monitoring, humidification control, heat exchanger antifreeze control, inverter control, external signal linkage.

● Real-time tracking and recording of unit operating efficiency.

● Provides protection functions such as motor start timeout, overload, phase loss, imbalance, underload, leakage, blockage, etc.

● Self-diagnostic function, provides unit fault location and cause for quick equipment maintenance.

ECS-7000MD Chilled Water Pump Controller

Product Features

● Integrates secondary circuits of chilled water pump electrical control cabinets.

● Manual remote-automatic control, interlock control, pump group status display, pump group combination configuration, and automatic wear balancing function.

● Real-time tracking and recording of unit operating efficiency.

● Provides protection functions such as pump group motor start timeout, overload, phase loss, imbalance, underload, leakage, blockage, etc.

● Self-diagnostic function, provides unit fault location and cause for quick equipment maintenance.

ECS-7000MZK Cooling and Heat Source Cluster Controller

Product Features

● Performs cluster control of cooling and heat source equipment, chilled water pump groups, cooling water pump groups, and cooling tower groups.

● Real-time tracking and recording of unit operating efficiency.

● Real-time tracking and recording of unit operating efficiency.

● Provides protection functions such as pump group motor start timeout, overload, phase loss, imbalance, underload, leakage, blockage, etc.

● Self-diagnostic function, provides unit fault location and cause for quick equipment maintenance.

For detailed product information, configuration solutions, product prices, product technical parameters;

You can contact the manufacturer: Manager Liu 13572979371 13572979371 (same WeChat VX)

To obtain your exclusive solution

Industry Category Measurement-Analysis-Instruments
Product Category
Brand: 西安
Spec:
Stock: 1000
Manufacturer:
Origin: China / Shaanxi / Xianshi
About Toocle.com - Partner Programme - Old Version
Copyright © Toocle.com. All Rights Reserved.
(浙)-经营性-2023-0192